Dual Source CT Visualization of thrombosed Aortocoronary Venous Bypass graft

SOMATOM Definition

Christoph Becker, MD
Department of Radiology, University Hospital of Munich-Großhadern, Germany

 |  2008-02-27

History

A 64 year-old male patient with chest pain with known coronary artery disease (CAD) and after bypass surgery was referred for a Dual Source CT. A scan from the aortic arch to the apex was performed with 140ml of Ultravist 370 followed by a slain chaser bolus of 100ml.

 

Diagnosis
Visualization of 5 bypass grafts. Three of them are patent (left internal mammarian artery-bypass leading to left anterior descending artery, Radial artery to the first diagonal branch, one aortocoronary venous bypass leading to the Circumflex artery). The fourth aortocoronary venous bypass is leading to the left anterior descending recently occluded by a large thrombus. From a CT morphological aspect (density in side the thrombus 67 HU) the occlusion is not older than 3 month. The last venous bypass graft is leading to the right coronary artery and already occluded since a longer time (already organized and not anymore visible).

 

Comments
With the high tempo resolution of 82ms the bypasses and the anastomosis are sharp displayed. With the visualization of VRT display in one view the status of the bypass grafts is detected. The CT images give also morphological information of the vessel lumen and gives hints about the time point of occlusion which has impact on therapy.

 

 

Visualization of 5 bypass grafts. Three with normal flow and one with a large thrombus in the aortocoronary venous bypass going to the LAD and the fifth is chronically occluded.

Examination Protocol

Scanner
SOMATOM Definition
Scan area
Heart
Scan length 190 mm
Scan time 17 s
Scan direction Caudo-cranial
kV
120 kV
Effective mAs
265 mAs / rot
Rotation time
0.33 s
Slice collimation
0.6 mm
Reconstructed slice thickness
0.75 mm
Increment 0.5 mm
CTDIvol
25.33 mGy
Kernel
B26f

 

La información presentada es solamente para ilustración del lector y no debe usarse como instrucciones para la práctica médica. Cualquier practicante del cuidado de la salud que lea esta información deberá usar su propio conocimiento, capacitación y experiencia en el tratamiento de sus pacientes. Este material no sustituye dicho deber y Siemens Healthineers no lo pone a disposición para ningún propósito al respecto.

Los fármacos y dosis mencionados en el presente son consistentes con la etiqueta de aprobación para usos y/o indicaciones del fármaco. El médico que lo trata es completamente responsable del diagnóstico y tratamiento de los pacientes, incluyendo los medicamentos y dosis prescritas en relación con dicho uso. Las instrucciones de funcionamiento se deben seguir con cuidado cuando se usa el sistema. El origen de los datos técnicos es correspondiente a las fichas técnicas. Los resultados pueden variar.